Validation¶
This section collects the evidence that zvDVC’s results are right: against a known answer, against its own error floor, and against iDVC, the established code it reimplements. It is for anyone deciding whether to rely on zvDVC’s numbers, and for reviewers of work that uses them.
Three kinds of evidence, each answering a different question:
Question |
Evidence |
Page |
|---|---|---|
Does zvDVC give the same answer as iDVC? |
iDVC’s engine (CCPi DVC 22.0.0) and zvDVC on iDVC’s own example data and settings, point by point |
|
Is the answer correct? |
Synthetic volume pairs with a known displacement field, solved by both codes and scored against the truth |
|
How precise can any answer be on real data? |
The case A scan shifted by known sub-voxel amounts, and repeat solves with different sample points |
|
Does this hold on other data, against a known answer? |
Both codes on public benchmarks: repeat scans and stage moves of a real CT sample, and synthetic translations and stretches |
Summary¶
Check |
Criterion |
Result |
|---|---|---|
Agreement with iDVC, case A (4 628 interior points) |
status agreement ≥ 98 % |
100 % |
mean difference ≤ 0.01 voxel per axis |
0.0032 at most |
|
spread no larger than iDVC’s own run-to-run spread |
the same: SD 0.048 / 0.043 / 0.045 voxel against 0.048 / 0.044 / 0.046 |
|
with identical sample points, both run to convergence |
median 2.1 × 10⁻⁵ voxel, the order of iDVC against a recompiled iDVC |
|
Accuracy against a known field, case S (affine, 2 % noise, 12-DOF) |
RMSE ≤ 0.05 voxel, ≥ 99 % GOOD |
0.0103 per axis, 100 % GOOD; iDVC’s engine: 0.0103 |
Interpolation bias on the real scan |
none required; reported |
±0.03 voxel without prefilter (as iDVC); 0.0005 with prefilter σ = 1 |
Sampling uncertainty on the real scan |
none required; reported |
0.032 voxel per axis at iDVC’s 8 000 samples, falling as 1/√n |
Agreement with iDVC, public datasets (23 cases, 23 944 points GOOD in both) |
none set; reported |
median difference 0.00005–0.0006 voxel per case |
Noise floor, DVC Challenge 1.0 XCT1 repeat scans |
zvDVC’s SD within 1.5 × iDVC’s; ≤ 0.05 voxel at a 32-voxel subvolume |
the same as iDVC’s: 0.0095 voxel |
Known translations (0–1 voxel) and stretches (5, 10 %), DVC Challenge 2.0 beads |
bias ≤ 0.02 voxel; strain error ≤ 10⁻³ |
bias ≤ 0.0003, RMSE 0.004–0.006, fitted strain within 1.3 × 10⁻⁵, in both codes |
Stretches of 15–30 % at iDVC’s settings |
none set; reported |
both codes fail; iDVC’s engine reports 55–91 % of points GOOD but wrong, zvDVC 3–5 % |
zvDVC against iDVC’s engine on iDVC’s example data, every interior point (Agreement with iDVC on its test dataset).¶
What has not been validated yet¶
Other materials and scanners. Beyond case A, one real CT system (DVC Challenge 1.0, XCT1) and one synthetic bead family have been run (Public validation datasets). Five more scanners in the same archive, bone and a second independent code are listed there, not yet run.
Strain. zvDVC’s strain follows CCPi’s method and agrees with CCPi’s
strainat interior points (Strain and displacement uncertainty). A strain fitted to a whole displacement field matches known stretches (Public validation datasets), but pointwise strain has not been checked against a known field.Large runs. The tiled pipeline matches the in-memory solve bit for bit on the CPU engines; multi-GPU runs on 8 × H100 have not been made (MVP review, 2026-09-29).